Error (175006): Could not find path between source pin and the global clock driver - Error (175006): Could not find path between source pin and the global clock driver Description You may see this error message in the Intel® Quartus® Prime Software when targetting an Intel® Arria® 10 device and you have connected the Clock Control Block (ALTCLKCTRL) IP inclk port to a dedicated clock input pin which differs from the Pin Mapping in Arria 10 Devices. Resolution Ensure that ALTCLKCTRL inclk is connected to the correct dedicated clock input pin as in Pin Mapping in Intel® Arria® 10 Devices . Custom Fields values: ['novalue'] Troubleshooting FB: 381563; False ['ALTCLKCTRL IP'] ['novalue'] novalue novalue ['Arria® 10 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2023-01-24