Why does configuration fail intermittently when using a JIC file generated with Quartus® Prime Pro Edition version 23.2 and later on Agilex™ 7 FPGA devices, resulting in Major Error Code 0x0000F004 and Minor Error Code 0x00000001? - Why does configuration fail intermittently when using a JIC file generated with Quartus® Prime Pro Edition version 23.2 and later on Agilex™ 7 FPGA devices, resulting in Major Error Code 0x0000F004 and Minor Error Code 0x00000001?
Description You may encounter the following errors during configuration using a JIC file generated with Quartus® Prime Pro Edition software version 23.2 and later, targeting Agilex™ 7 FPGA devices with P-tile and/or E-tile: Major Error Code: 0x0000F004 Minor Error Code: 0x00000001 This issue affects Agilex™ 7 FPGA devices with P-tile and/or E-tile during configuration. Resolution To work around this issue: Power cycle the board or toggle nCONFIG to reconfigure the FPGA. Patches are also available to fix this problem for the following Quartus® Prime Pro versions: 23.2 23.3 24.3.1 25.1 This problem is fixed starting from Quartus® Prime Pro Edition version 25.1.1 and later. Related Articles Note: If you can tolerate occasional errors that are unlikely to recur after reconfiguration, no further action is necessary . If you require zero-error tolerance —even for rare occurrences that may be resolved through reconfiguration or toggling nCONFIG —a patch request is recommended . This fix does not require recompilation of the design. You only need to reconvert the .sof file to .jic .
Custom Fields values:
['novalue']
Troubleshooting
15016877623
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
25.1.1
23.2
['Agilex™ 7 FPGA F-Series']
['novalue']
['novalue']
['novalue'] - 2025-06-12
external_document
- Resource Type
- Support Resources > Knowledge Articles
- Source Name
- khoros