Why does SEU error detection fail to detect double-bit non-adjacent errors that occurred in the Agilex™ 7 devices? - Why does SEU error detection fail to detect double-bit non-adjacent errors that occurred in the Agilex™ 7 devices?
Description Due to a problem in Quartus® Prime Pro Edition Software version 23.2 and earlier, the SEU error queue will report a single-bit correctable error after a double-bit (non-adjacent) uncorrectable error has occurred. This problem may occur when the internal scrubbing feature is enabled in the Agilex™ 7 devices. SEU detection and internal scrubbing will stop working after reporting this single-bit correctable error. No SEU error will be reported or corrected, the SEU error message queue will be empty, and the SEU_ERROR pin will be de-asserted. Resolution This problem is fixed beginning with the Quartus® Prime Pro Edition Software version 23.3.
Custom Fields values:
['novalue']
Troubleshooting
15013393226
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
23.3
23.2
['Agilex™ 7 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2024-05-05
external_document