Why does the example testbench for Intel® Arria® 10 Triple-Speed Ethernet Intel® FPGA IP does not complete simulation? - Why does the example testbench for Intel® Arria® 10 Triple-Speed Ethernet Intel® FPGA IP does not complete simulation? Description Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 22.4, the testbench for TSE (SGMII + GXB) receives only three packets out of five and the simulation does not complete. The problem occurs because the MAC drops the frames with less than 7 bytes of Preamble. Resolution The patch for the Intel® Quartus® Prime Pro Edition Software version 22.4 can be downloaded from the following links: quartus-22.4-0.10-windows.exe for Intel® Quartus® Prime Pro Edition Software for Windows quartus-22.4-0.10-linux.run for Intel® Quartus® Prime Pro Edition Software for Linux quartus-22.4-0.10-readme.txt Readme The problem has been fixed starting in the Intel® Quartus® Prime Pro Edition Software v23.1. Custom Fields values: ['novalue'] Troubleshooting 18026723617 False ['Triple-Speed Ethernet IP'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 23.1 22.4 ['Arria® 10 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2023-03-01