The auto-constraining script was not able to detect any PLLs in the < instname > memory interface. - The auto-constraining script was not able to detect any PLLs in the < instname > memory interface.
Description The following critical warnings may occur when a SystemVerilog or VHDL generate statement is used for creating the DDR3 or DDR4 instances in a design: Critical Warning: The auto-constraining script was not able to detect any PLLs in the <instname> memory interface. Critical Warning: Verify the following: Critical Warning: The core <instname> is instantiated within another component (wrapper) Critical Warning: The core is not the top-level of the project Critical Warning: The memory interface pins are exported to the top-level of the project The problematic line in the pin_map.tcl file is in the get_p2c_c2p_clock_uncertainty procedure: set pll_atoms [get_atom_nodes -matching *${instname}|*:arch|*:arch_inst|*:pll_inst|* -type IOPLL] Resolution Open the pin_map.tcl file, replace *${instname} with *, and re-compile. The design should compile without the critical warnings. This issue will be fixed in a future version of the Quartus® II software.
Custom Fields values:
['novalue']
Troubleshooting
novalue
False
['novalue']
['FPGA Dev Tools Quartus II Software']
novalue
14.0a10
['Programmable Logic Devices']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document