Why can't I connect the transceiver reconfig_to/from_xcvr ports between the Reconfiguration Controller and the 1G/10GbE and 10GBASE-KR PHY IP in the Platform Designer on Stratix® V GX devices using the Quartus® II software v2.1 and earlier? - Why can't I connect the transceiver reconfig_to/from_xcvr ports between the Reconfiguration Controller and the 1G/10GbE and 10GBASE-KR PHY IP in the Platform Designer on Stratix® V GX devices using the Quartus® II software v2.1 and earlier?
Description It is not possible to connect the transceiver reconfig_to /from _xcv r ports between the reconfiguration controller and the 1G/10GbE and 10GBASE-KR PHY IP in the Platform Designer on Stratix® V GX devices due to a bug in the Quartus® II software v12.1 and earlier. Resolution To work around this problem, export the reconfig_t o/from _xcvr ports of the transceiver Reconfiguration Controller and the 1G/10GbE and 10GBASE-KR PHY IP and connect in your RTL. This problem is fixed in the Quartus II software v13.0.
Custom Fields values:
['novalue']
Troubleshooting
2205798165
False
['novalue']
['FPGA Dev Tools Quartus II Software']
13.0
12.1
['Stratix® V GX FPGA']
['novalue']
['novalue']
['novalue'] - 2023-03-23
external_document