Error 12077: Node instance "lpm_mult_component" instantiated with unknown parameter "lpm_hint" - Error 12077: Node instance "lpm_mult_component" instantiated with unknown parameter "lpm_hint"
Description Due to a problem in the Intel® Quartus® Prime Pro/Standard Edition Software version 19.3 and earlier, you will see the following error when you name the LPM_MULT Intel® FPGA IP generated file as "lpm_mult": Error 12077: Node instance "lpm_mult_component" instantiated with unknown parameter "lpm_hin t" Resolution To work around this problem, give the LPM_MULT Intel® IP another file name other than "lpm_mult".
Custom Fields values:
['novalue']
Troubleshooting
1507309617
False
['LPM_MULT IP']
['FPGA Dev Tools Quartus® Prime Software Pro', 'FPGA Dev Tools Quartus® Prime Software Standard']
novalue
18.1
['Programmable Logic Devices']
['novalue']
['novalue']
['novalue'] - 2023-11-13
external_document