Why am I unable to detect the EPCQ-L device connected to my Arria 10 device, after instantiating the Serial Flash Loader (SFL) IP in my user design in Quartus Prime Pro? - Why am I unable to detect the EPCQ-L device connected to my Arria 10 device, after instantiating the Serial Flash Loader (SFL) IP in my user design in Quartus Prime Pro?
Description Due to a known issue in the Quartus ® Prime Pro software version 15.1.2 or earlier, you may not be able to detect the EPCQ-L configuration even after you have instantiated the SFL IP core in your Arria ® 10 design. Resolution This issue is scheduled to be fixed in a future release of the Quartus Prime Pro software. Use the factory default enhanced SFL image instead of instantiating the IP core in your design as a temporary workaround.
Custom Fields values:
['novalue']
Troubleshooting
novalue
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
novalue
15.1.2
['Programmable Logic Devices']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document