The data ports do not connect to ALTDDIO registers, but the data rate is set to double the data rate. - The data ports do not connect to ALTDDIO registers, but the data rate is set to double the data rate. Description Due to a problem in the Intel® Quartus® Prime Standard Edition Software version 18.1 and earlier, you may see this error message if you launch the I/O Timing Constrainer in the NIOS® II command shell. This is because you have a soft LVDS Intel® FPGA IP in your design, and the I/O Timing Constrainer failed to run at double the data rate. Resolution To work around this problem, write the c onstraint in the <project>.sdc instead of using the I/O Timing Constrainer in the NIOS® II command shell. Custom Fields values: ['novalue'] Troubleshooting 1507099719 False ['novalue'] ['FPGA Dev Tools Quartus® Prime Software Standard'] novalue 18.1 ['Programmable Logic Devices'] ['novalue'] ['novalue'] ['novalue'] - 2023-01-05