Why doesn’t the F-Tile FHT Transceiver Toolkit RX PRBS checker work in the Intel® Quartus® Prime Pro Edition Software v21.3 ? - Why doesn’t the F-Tile FHT Transceiver Toolkit RX PRBS checker work in the Intel® Quartus® Prime Pro Edition Software v21.3 ? Description Due to problems in the F-Tile Transceiver Toolkit in the Intel® Quartus® Prime Pro Edition Software v21.3, the F-Tile Transceiver Toolkit reports errors when the RX PRBS checker of FHT PMA configured in NRZ modulation is started. Resolution A patch is available to fix this problem for the Intel Quartus Prime Pro Edition Software v21.3. Download and install patch 0.16 from the following links: Patch 0.16 for Windows Patch 0.16 for Linux Readme for patch 0.16 This problem is fixed beginning with the Intel® Quartus® Prime Pro Edition Software v22.3. Custom Fields values: ['novalue'] Troubleshooting 1509992931 False ['novalue'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 22.3 21.3 ['Agilex™ 7 FPGA F-Series', 'Agilex™ 7 FPGA I-Series'] ['novalue'] ['novalue'] ['novalue'] - 2023-01-10

external_document