Why are MT25QL128, MT25QL01G and MT25QL02G flash devices missing from the Remote Update FPGA IP configuration device list in the Quartus® Prime Software version 18.1? - Why are MT25QL128, MT25QL01G and MT25QL02G flash devices missing from the Remote Update FPGA IP configuration device list in the Quartus® Prime Software version 18.1?
Description Due to a known problem in Quartus® Prime Standard Software version 18.1, Micron* flash devices MT25QL128, MT25QL01G and MT25QL02G are not listed in the Remote Update FPGA IP configuration device list. Resolution To work around this problem, select a Macronix* flash part with the same density in the configuration device list of the Remote Update FPGA IP but do not check the “Enable reconfig POF checking” option.
Custom Fields values:
['novalue']
Troubleshooting
FB: 596433;
False
['Remote Update IP']
['FPGA Dev Tools Quartus® Prime Software Standard']
No plan to fix
18.1
['Programmable Logic Devices']
['novalue']
['novalue']
['novalue'] - 2024-10-31
external_document