Why does configuration intermittently fail when using a JIC file generated with Quartus® Prime Pro Edition version 24.2 and later on Agilex™ 7 FPGA devices, resulting in Major Error Code 0x0000F004 and Minor Error Code 0x0000D006? - Why does configuration intermittently fail when using a JIC file generated with Quartus® Prime Pro Edition version 24.2 and later on Agilex™ 7 FPGA devices, resulting in Major Error Code 0x0000F004 and Minor Error Code 0x0000D006? Description You may encounter the following errors during configuration using a JIC file generated with Quartus® Prime Pro Edition version 24.2 and later , targeting Agilex™ 7 FPGA devices with F-tile and/or R-tile : Major Error code: 0x0000F004; Minor Error Code: 0x0000D006; This issue affects configuration behavior on Agilex™ 7 FPGA devices with F-tile and/or R-tile . Resolution To work around this issue: Power cycle the FPGA. Note: Triggering nCONFIG will not resolve the issue. Patches are also available to fix this problem for the following Quartus® Prime Pro version: 24.2: Quartus Prime Pro Edition Design Software v24.2 patch 0.59fw 25.1: Quartus Prime Pro Edition Design Software v25.1 patch 0.25fw This problem is fixed starting from Quartus® Prime Pro Edition version 25.1.1 and later. Custom Fields values: ['novalue'] Troubleshooting 15017359155 False ['novalue'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 25.1.1 24.2 ['Agilex™ 7 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2025-07-30