Why doesn't the NCO IP output start from Channel 1 in some cases of multi-channel implementations? - Why doesn't the NCO IP output start from Channel 1 in some cases of multi-channel implementations? Description Starting in Intel® Quartus® Prime software version 16.1, of the NCO IP Core, the multi-channel behavior differs than described in the documentation. For multi-channel implementations over 3 channels, the data is initially output out of order. An example behavior of the IP based on different multi-channel implementations is described below: 3 Channels: CH3, CH1, CH2 4 Channels: CH3, CH4, CH1, CH2 5 Channels: CH3, CH4, CH5, CH1, CH2 6 Channels: CH3, CH4, CH5, CH6, CH1, CH2 Resolution The NCO IP Core outputs valid data after the initial incorrect data order. Please ignore the first N-2 data values where N is equal to the number of channels. This problem is scheduled to be fixed in a future release of the Intel® Quartus® Prime software. Custom Fields values: ['novalue'] Troubleshooting 558329 False ['NCO IP'] ['FPGA Dev Tools Quartus® Prime Software Pro'] novalue 16.1 ['Programmable Logic Devices'] ['novalue'] ['novalue'] ['novalue'] - 2021-08-25