Why is Quartus® Prime Pro software showing a fitter error when assigning differential IO pins for Agilex™ 7 FPGA M-series even after following the IO pin assignment restrictions? - Why is Quartus® Prime Pro software showing a fitter error when assigning differential IO pins for Agilex™ 7 FPGA M-series even after following the IO pin assignment restrictions?
Description Altera® Quartus® Prime Pro software version 24.3.0 will show fitter error when you assign Agilex™ 7 FPGA M-series differential IOs using pin planner even you followed the IO assignment restrictions. Placement Restrictions for True Differential and Single-Ended I/O Standards in the Same or Adjacent GPIO-B Bank . Resolution This is Quartus® Prime Pro software version 24.3.0 issue. This issue has been fixed in Quartus® Prime Pro 24.3.1.
Custom Fields values:
['novalue']
Troubleshooting
15017534164
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
24.3.1
24.3
['Agilex™ 7 FPGA M-Series']
['novalue']
['novalue']
['novalue'] - 2025-06-16
external_document