How to fix Error(23782): Failed to find an expected report - How to fix Error(23782): Failed to find an expected report
Hey Altera Community I was messing around in the Board and IP settings trying to get simulation to work, but something went wrong and now I get this error every time I try to compile. How to fix? Info: Finished generating IP file(s) in the project. Error(23782): Failed to find an expected report while writing reporting database. Error: Quartus Prime IP Generation Tool was unsuccessful. 1 error, 6 warnings
Replies:
Re: How to fix Error(23782): Failed to find an expected report
Hi Mads, Thank you for the update! I'm glad to hear that from you. As the problem is now resolved, I will proceed with closing this case. We will continue to monitor this post for the next 5 days. If there are no further inquiries during this period, I will step back and allow the community to assist with any future follow-up questions. Thank you for engaging with us! Best regards, ZiYingE_Altera
Replies:
Re: How to fix Error(23782): Failed to find an expected report
I deleted the entire folders of "qdb" and "output_files"
Replies:
Re: How to fix Error(23782): Failed to find an expected report
Hi Mads, That's great news! I'm glad to hear the issue is now resolved. Thank you for your patience and for trying the different suggestions I provided. When you have a moment, could you let me know which specific solution helped resolve the issue? It would be very helpful for our records and for assisting other customers who may face a similar situation. Regards, ZiYingE_Altera
Replies:
Re: How to fix Error(23782): Failed to find an expected report
Hi Mads, If this issue started after modifying the Board or IP settings, it is due to some of the generated database files no longer match the current project configuration and have become out of sync. Here are a few suggestions you can try: 1. Delete the project database folders and recompile Close Quartus and delete the following folders from your project directory: db/ incremental_db/ output_files/ Then reopen the project and run a full compilation. This will force Quartus to regenerate the project database and output files from scratch. 2. Regenerate your IPs Since the error occurs during IP generation, the generated IP output files may no longer be consistent with the current Board/IP settings. Go to Project → Upgrade IP Components and regenerate all IPs If you are using Platform Designer , open the system and regenerate the Platform Designer output files as well. 3. Check on the modified board Navigate to Assignments → Device and confirm that the selected board/device matches your intended target device. A mismatch between the project settings and generated IP files can sometimes lead to unexpected compilation or IP generation errors. 4. Launching Quartus as Administrator You may also try launching Quartus Prime as Administrator and regenerate the IP. We have seen cases where IP-related file generation behaves differently when Quartus does not have sufficient permissions to create or update certain files. If the suggestions above do not resolve the issue, could you please provide the following information? Quartus version and edition (Lite, Standard, or Pro) Operating system (Windows, Linux, etc.) If using Windows, please provide the Windows version Target FPGA device or device family Whether the project compiled successfully before the Board/IP setting changes were made The complete error log, including any messages shown before Error (23782) If possible, could you share the project files? Looking forward to your update. Thank you! Regards, ZiYingE_Altera - 2026-06-24