Why does Ashling* RiscFree* IDE for Altera® FPGAs fail to debug a Nios® V processor C++ software project in Windows? - Why does Ashling* RiscFree* IDE for Altera® FPGAs fail to debug a Nios® V processor C++ software project in Windows?
Description Due to a problem with the Ashling* RiscFree* IDE for Altera ® FPGAs software, debugging a Nios ® V processor software project may fail when it is written in the C++ language. This is because there is a bug in the processor toolchain from the Ashling* RiscFree* IDE for Altera ® FPGAs software. C projects are not affected by this issue. You might receive the following error messages. Error Messages How is RISC-V GDB executed? Error in services launch sequence: GDB prompt not read From Ashling* RiscFree* IDE for Altera software ../../../gdb/gdb/cp-name-parser.y:192: internal-error: fill_comp: Assertion ‘i’ failed. Executing riscv32-unknown-elf-gdb commands in the command-line interface The affected Ashling* RiscFree* IDE for Altera ® FPGAs software versions are: 24.3.1 (version dated 9 th Aug 2024) 24.4.0 (version dated 27 th Sep 2024) 25.1.1 (version dated 31 st Jan 2025) Note that: This problem only affects Windows environments. C projects are not affected by this problem. Resolution This problem is fixed beginning with the Ashling* RiscFree* IDE for Altera ® FPGAs software version 25.2.1 (version dated 9 th May 2025). You can download Ashling* RiscFree* IDE for Altera ® FPGAs software version 25.2.1 (version dated 9 th May 2025) separately from Quartus® Prime Pro Edition Installer for software version 25.1.1. Follow these steps: Go to the Quartus® Prime Pro Edition Installer for software version 25.1.1 download link . Select Windows as the Operating System . Download the Quartus® Prime Pro Edition Installer for software version 25.1.1. Launch the installation. Select the following files to install: Add-ons and Standalone Software > Ashling* RiscFree* IDE for Altera Add-ons and Standalone Software > Quartus ® Prime Pro Edition Programmer and Tools Note: Refrain from using the Quartus® Prime Pro Edition Installer for software version 25.3 to resolve this problem. The installer contains the older version of the Ashling* software (Software version 25.1.1).
Custom Fields values:
Troubleshooting
18043318836
['FPGA Dev Tools Quartus® Prime Software Pro', 'FPGA Dev Tools Quartus® Prime Software Standard']
25.1.1
24.3.1
['Arria® 10 FPGAs and SoCs', 'Arria® V FPGAs and SoCs', 'Arria® II FPGAs', 'Cyclone® 10 FPGAs', 'Cyclone® 10 LP FPGA', 'Cyclone® 10 GX FPGA', 'Cyclone® V FPGAs and SoCs', 'Cyclone® IV FPGAs', 'MAX® 10 FPGA', 'MAX® II CPLD', 'MAX® V CPLD', 'Stratix® 10 FPGAs and SoCs', 'Stratix® IV FPGAs', 'Stratix® V FPGAs', 'Agilex™ 3 FPGAs and SoCs', 'Agilex™ 5 FPGAs and SoCs', 'Agilex™ 7 FPGAs and SoCs']
['Non-Commercial Product'] - 2025-12-14
external_document