Why are additional transceiver banks available in my Cyclone V device? - Why are additional transceiver banks available in my Cyclone V device?
Description Cyclone® V FPGA transceiver banks are grouped and named differently than Stratix® V or Arria® V devices. The Cyclone V transceiver banks consist of 3 transceivers per bank rather than the 6 that are found in Stratix V and Arria V devices. Internal Cycone V clocking including x6 and xN clock networks are similar to the Stratix V and Arria V devices. The additional transceiver banks in Cyclone V are confined to a difference in name only. Some earlier versions of the Cyclone V Handbook may show 6 transceivers per bank but this is incorrect and will be updated in a future release. Quartus® II already reflects this name change as shown in the Pin Planner, output reports, etc., and pinout spreadsheets available on the Altera website also reflect this name change.
Custom Fields values:
['novalue']
Troubleshooting
novalue
False
['novalue']
['novalue']
novalue
novalue
['Cyclone® V FPGAs and SoCs', 'Cyclone® V GT FPGA', 'Cyclone® V GX FPGA', 'Cyclone® V ST FPGA', 'Cyclone® V SX FPGA']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document