Why does the word aligner not work correctly with the synchronization state machine when I check Enable word aligner output reverse bit ordering option in Stratix II GX ALT2GXB MegaWizard? - Why does the word aligner not work correctly with the synchronization state machine when I check Enable word aligner output reverse bit ordering option in Stratix II GX ALT2GXB MegaWizard?
Description When you check “Enable word aligner output reverse bit ordering” option in Stratix® II GX ALT2GXB MegaWizard, the word aligner does not work correctly with synchronization state machine, because the synchronization state machine does not work in this case. This is hardware limitation. Use manual alignment mode instead of synchronization state machine.