Why are OCT nodes listed at No Clock section in the Check Timing report in the TimeQuest timing analyzer? - Why are OCT nodes listed at No Clock section in the Check Timing report in the TimeQuest timing analyzer?
Description In the Quartus® II software, the Check Timing report in the TimeQuest Timing analyzer may list the following on-chip termination (OCT) nodes in the No Clock section for designs targeting Stratix® IV devices and using DDR3 SDRAM Controller MegaCore® supporting UniPHY: <hierarchical path> |altera_mem_if_oct_stratixiv:oct0|wire_sd1a_terminationcontrol[0] <hierarchical path> |altera_mem_if_oct_stratixiv:oct0|wire_sd1a_serializerenableout[0] Resolution These warnings can safely be ignored.
Custom Fields values:
['novalue']
Troubleshooting
novalue
False
['novalue']
['novalue']
novalue
novalue
['Stratix® IV E FPGA', 'Stratix® IV GT FPGA', 'Stratix® IV GX FPGA']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document