Why doesn't read data return as expected from an Avalon-MM slave ? - Why doesn't read data return as expected from an Avalon-MM slave ? Description Due to a problem in the Quartus® II software version 12.1 and earlier, read data may not return as expected when the Avalon-MM master's data port bit width is wider than the Avalon-MM slave's port bit width (for example: master bit width=64 bits, slave bit width=32 bits) and the Maximum pending read transactions parameter on the Avalon-MM Master is greater than 1. Resolution To work around this problem, set the same bit-width on both the master and slave port, or set the Maximum pending read transactions parameter to 1 on Avalon-MM master. This problem is scheduled to be fixed in a future release of the Quartus II software. Custom Fields values: ['novalue'] Troubleshooting novalue False ['novalue'] ['FPGA Dev Tools Quartus II Software'] novalue 12.1 ['Programmable Logic Devices'] ['novalue'] ['novalue'] ['novalue'] - 2021-08-25