Why doesn't the CNT_RESET register of the Triple Speed Ethernet MegaCore Function clear the 64-bit statistic counters? - Why doesn't the CNT_RESET register of the Triple Speed Ethernet MegaCore Function clear the 64-bit statistic counters?
Description Due to a problem in the Triple Speed Ethernet (TSE) MegaCore® Function, the CNT_RESET register does not clear the following 64-bit statistic counters. aOctetsTransmittedOK aOctetsReceivedOK etherStatsOctets Resolution Set SW_RESET to 1 to clear the octet counters. This problem will be fixed in a future version of the Quartus® II software.