Why do I see read or write transactions on the BAM or H2D MM/H2D ST device port of the Scalable Scatter-Gather DMA FPGA IP not completed? - Why do I see read or write transactions on the BAM or H2D MM/H2D ST device port of the Scalable Scatter-Gather DMA FPGA IP not completed? Description Due to a problem in the Quartus® Prime Pro Edition Software version 24.2, transactions of the Scalable Scatter-Gather DMA FPGA IP may not be completed when the connected downstream AXI-4/AXI-ST Subordinate or Avalon-ST Sink port did not respond to the BAM or H2D MM/H2D ST interface. This problem does not impact the D2H ST interface. Resolution For BAM transactions that cannot be completed, this problem can be recovered by resetting the Scalable Scatter-Gather DMA FPGA IP. For H2D MM/H2D ST transactions that cannot be completed, this problem can be recovered by resetting respective H2D MM/H2D ST interface. This problem is scheduled to be fixed in a future release of the Quartus® Prime Pro Edition Software. Custom Fields values: ['novalue'] Troubleshooting 15014744184 False ['Scatter-Gather DMA Controller IP'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 24.3 24.2 ['Agilex™ 5 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2025-06-03