How do I use the CHANGE_EDREG instruction to simulate a CRC error in Intel® Cyclone® 10 LP device? - How do I use the CHANGE_EDREG instruction to simulate a CRC error in Intel® Cyclone® 10 LP device?
Description You can perform CHANGE_EDREG using quartus_jli command with an appropriate JAM STAPL Format File (.jam) file in Intel® Cyclone® 10 LP device. You can download an example crc-edreg-c.jam . Here are the steps to execute quartus_jli command with the example .jam file Connect your PC to your Intel Cyclone 10 LP device through a download cable Configure your Intel Cyclone 10 LP device Open a command prompt when using Windows or a command shell when using Linux Execute the following command quartus_jli -c <cable number> -a CONFIG_IO crc-edreg-c.jam The cable number can be identified by using jtagconfig command. After CHANGE_EDREG is executed successfully, the 32-bit storage register of the error detection block is modified and a CRC error is detected.
Custom Fields values:
['novalue']
Troubleshooting
1507214256
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
novalue
18.1
['Cyclone® 10 LP FPGA']
['novalue']
['novalue']
['novalue'] - 2022-01-19
external_document