Why are there errors while generating an example design using GTS Transceiver with Dynamic Reconfiguration (DR) between two rates in the Quartus® Prime Pro Edition software version 25.1? - Why are there errors while generating an example design using GTS Transceiver with Dynamic Reconfiguration (DR) between two rates in the Quartus® Prime Pro Edition software version 25.1?
Description Performing DR between two rates using the GTS Transceiver was throwing an error when using manual adaptation mode during example design generation. The errors reported in the IP Catalog GUI during the generation process appear due to the in-built functionality of adaptation mode being set to disabled in the simulation. Due to the disabled adaptation mode, any non-zero values for RX PMA analog parameters in simulation mode throw an error. Resolution To work around this problem in the Quartus® Prime Pro Edition software version 25.1, set RX PMA analog parameters in the IP Catalog GUI to 0. This problem is scheduled to be fixed in a future release of the Quartus® Prime Pro Edition software.
Custom Fields values:
['novalue']
Errata
14024506354
False
['SM Dynamic Reconfiguration Suite IP']
['FPGA Dev Tools Quartus® Prime Software Pro']
novalue
25.1
['Agilex™ 5 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2025-05-18
external_document