Internal Error: Sub-system: REGPACK, File: /quartus/qcl/regpack/regpack_util.cpp, Line: 1190 - Internal Error: Sub-system: REGPACK, File: /quartus/qcl/regpack/regpack_util.cpp, Line: 1190
Description Due to a problem in the Quartus® Prime Pro Edition Software version 23.4 and earlier, you might see this internal error during the Plan stage of the Fitter. This problem can occur on the Arria® 10 and Cyclone® 10 DSP IPs since they do not have the input_systolic_clken or input_systolic_clock parameters. Resolution To work around this problem, follow these steps in any order: Prevent output register packing by applying assignments on registers (1 is sufficient) or modify the RTL to move these registers to the input. eg. set_instance_assignment -name QII_AUTO_PACKED_REGISTERS OFF -to p_o[0]~reg0 -entity <name> Add synchronizer detection off assignments to all input registers. eg. (* altera_attribute = {" -name SYNCHRONIZER_IDENTIFICATION OFF "} *) logic signed [DATA_WIDTH-1:0] <input register>[1:0]; This problem is fixed starting in version 24.1 of the Quartus® Prime Pro Edition Software.
Custom Fields values:
['novalue']
Troubleshooting
14020901605
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
24.1
23.3
['Arria® 10 FPGAs and SoCs', 'Cyclone® 10 FPGAs']
['novalue']
['novalue']
['novalue'] - 2023-12-13
external_document