Is there a known issue with the ALTREMOTE_UPDATE megafunction for Stratix V and Arria V devices? - Is there a known issue with the ALTREMOTE_UPDATE megafunction for Stratix V and Arria V devices?
Description Yes, there is a known issue with the ALTREMOTE_UPDATE megafunction for Stratix® V and Arria® V devices. The logical atom definition for stratixv_rublock and arriav_rublock in the WYSIWYG atom for Stratix V and Arria V devices were defined incorrectly. Thus, the megafunction will fail to function correctly in these devices. Resolution This issue has been fixed in the Quartus® II software version 11.1SP2 or later. If you are using Quartus II software version prior to 11.1SP2, recompile your design using Quartus II software version 11.1SP2 or later.
Custom Fields values:
['novalue']
Troubleshooting
novalue
False
['novalue']
['FPGA Dev Tools Quartus II Software']
novalue
11.1.1
['Arria® V GT FPGA', 'Arria® V GX FPGA', 'Arria® V ST FPGA', 'Arria® V SX FPGA', 'Stratix® V E FPGA', 'Stratix® V GS FPGA', 'Stratix® V GT FPGA', 'Stratix® V GX FPGA']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document