Error (129029): Input port CLK on atom "<DLL instance>", which is a arriav_dll primitive, is not connected to a valid source File: /dll.v Line: 53 - Error (129029): Input port CLK on atom "<DLL instance>", which is a arriav_dll primitive, is not connected to a valid source File: /dll.v Line: 53
Description The PLL output cannot be connected to the DLL directly when Enable access to dynamic phase shift ports is selected in the Altera PLL MegaWizard™ GUI. The Quartus® II software tries to insert the pll_dll_output atom between the PLL and DLL and causes the above fitter error. Resolution This problem has been fixed in Intel® Quartus® Prime Software version 13.1.
Custom Fields values:
['novalue']
Troubleshooting
2205800806
False
['PLL']
['FPGA Dev Tools Quartus II Software']
13.1
12.0.1
['Arria® V GT FPGA', 'Arria® V GX FPGA', 'Arria® V GZ FPGA', 'Arria® V ST FPGA', 'Arria® V SX FPGA']
['novalue']
['novalue']
['novalue'] - 2023-03-16
external_document