Why does my ethernet link partner report FCS errors when connected to 400GE-8 or 200GE-4 variants of the F-Tile Ethernet FPGA Hard IP when using the FGT PMA transceivers with ANLT over 1m of cable? - Why does my ethernet link partner report FCS errors when connected to 400GE-8 or 200GE-4 variants of the F-Tile Ethernet FPGA Hard IP when using the FGT PMA transceivers with ANLT over 1m of cable?
Description Due to a problem in the Quartus® Prime Pro Edition Software version 23.2 and later, ethernet link partners might report FCS errors when connected to 400GE-8 or 200GE-4 variants of the F-Tile Ethernet FPGA Hard IP when using ANLT with FGT PMA transceivers over 1m of cable. Resolution There is no workaround for this problem. This problem has been fixed in version 24.2 of the Quartus® Prime Pro Edition Software.
Custom Fields values:
['novalue']
Troubleshooting
16021952198
False
['F-Tile Ethernet Hard IP']
['FPGA Dev Tools Quartus® Prime Software Pro']
24.2
23.2
['Agilex™ 7 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2024-11-05
external_document