Why do I see Active Serial configuration fail with Intel® Stratix® 10 devices? - Why do I see Active Serial configuration fail with Intel® Stratix® 10 devices?
Description You may encounter Active Serial (AS) configuration failure when the Intel® Stratix® 10 device is powered up before the EPCQ-L serial configuration flash device is fully powered up. This issue impacts all Intel Stratix 10 devices. Resolution The EPCQ-L serial configuration flash device must be fully powered up at the same time or before ramping up VCCIO_SDM of Intel Stratix 10 devices.
Custom Fields values:
['novalue']
Troubleshooting
FB: 529902;
False
['novalue']
['novalue']
novalue
novalue
['Stratix® 10 GX FPGA', 'Stratix® 10 SX FPGA']
['novalue']
['Configuration Device EPCQ-L']
['novalue'] - 2021-08-25
external_document