Error: "Congested due to too much traffic at initiator <initiator> (the initiator capacity is [x]GB/s while the total requested bandwidth is [y]GB/s). Reduce traffic on this connection and other connections to this initiator to resolve this issue." - Error: "Congested due to too much traffic at initiator <initiator> (the initiator capacity is [x]GB/s while the total requested bandwidth is [y]GB/s). Reduce traffic on this connection and other connections to this initiator to resolve this issue." Description Due to a problem in Quartus® Prime Pro Edition Software version 24.2, when compiling an Agilex™ 7 FPGA HBM2E IP design with Fabric NoC enabled, you may encounter link bandwidth violations from the NoC Performance Report, which incorrectly flags links on the Fabric NoC. These false bandwidth violations do not have an impact on hardware performance. Resolution This problem is scheduled to be fixed in Quartus® Prime Pro Edition Software version 24.3.1. Custom Fields values: ['novalue'] Troubleshooting 14023072611 False ['NoC Initiator IP'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 24.3.1 24.2 ['Agilex™ 7 FPGA M-Series'] ['novalue'] ['novalue'] ['novalue'] - 2025-09-04