Error(20959): Module instance "emif_fm_hps_0|emif_fm_hps_0|arch|arch_inst|pll_inst|pll_inst", which is a tennm_iopll primitive, has unexpected connections on port LOCK. - Error(20959): Module instance "emif_fm_hps_0|emif_fm_hps_0|arch|arch_inst|pll_inst|pll_inst", which is a tennm_iopll primitive, has unexpected connections on port LOCK. Description Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 20.2 and earlier, you might see the following error message when you implement a design containing both the Intel Agilex® EMIF IP and the Intel Agilex® 3 HPS EMIF IP. Error(20959): Module instance "emif_fm_hps_0|emif_fm_hps_0|arch|arch_inst|pll_inst|pll_inst", which is a tennm_iopll primitive, has unexpected connections on port LOCK. Info(20960): Module: emif_fm_hps_0|emif_fm_hps_0|arch|arch_inst|pll_inst|pll_lock_issp|altsource_probe_body_inst|wider_probe_gen.wider_probe_inst|i118~1 Port: DATAC Resolution To work around this problem in the Intel® Quartus® Prime Pro Edition Software version 20.2 and earlier, delete or comment out the following assignment in the .qsf file: set_global_assignment -name VERILOG_MACRO "ALTERA_EMIF_ENABLE_ISSP=1 This problem is fixed in the Intel Quartus Prime Pro Edition Software version 20.3. Custom Fields values: ['novalue'] Troubleshooting 14012024294 True ['Memory Interfaces and Controllers'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 20.3 20.2 ['Agilex™ 7 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2023-01-25