Why does the example design fail to generate when "Dual Simplex Applied on JESD204B PHY" is selected with "Enable Manual F" enabled and the F value greater than 4? - Why does the example design fail to generate when "Dual Simplex Applied on JESD204B PHY" is selected with "Enable Manual F" enabled and the F value greater than 4?
Description Due to a problem in the Quartus® Prime Pro Edition software version 25.1, you may observe the Dual Simplex (DS) PHY wrapper example design for GTS JESD204B IP fails to generate when the JESD204B DS Wrapper option is used with "Dual Simplex applied on JESD204B PHY" selected in the IP GUI, "Enable Manual F" is enabled, and the F value is set greater than 4. Resolution This problem is fixed beginning with the Quartus® Prime Pro Edition version 25.3.1.
Custom Fields values:
['novalue']
Errata
QS-5577
novalue
['Interfaces JESD204B (Primary)']
['FPGA Dev Tools Quartus® Prime Software Pro']
25.3.1
25.1
['Agilex™ 5 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2026-05-26
external_document