Why Triple Speed Ethernet Shows Implicit Net Warning? - Why Triple Speed Ethernet Shows Implicit Net Warning?
Description The reset_n for pause generation stand/stop frame synchronizer is not driven properly. This causes reset_n to be stalled at VCC (inactive). Check the synthesis report for the following: • altera_eth_tse_std_synchronizer:XOFF_GEN_SYNC • altera_eth_tse_std_synchronizer:XON_GEN_SYNC ;reset_n;Input;Info;Stuck at VCC If reset_n is stuck at GND, this feature will not work. Resolution There is no workaround for this issue. This issue is fixed version 16.0 Update 2 of the Triple Speed Ethernet IP core.
Custom Fields values:
['novalue']
Troubleshooting
fb384843
True
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
16.0.2
16.0
['Programmable Logic Devices']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document