Why does the SmartVID (-V) graded Stratix® 10 FPGA device not respond to the master power management controller during the Partial Reconfiguration process? - Why does the SmartVID (-V) graded Stratix® 10 FPGA device not respond to the master power management controller during the Partial Reconfiguration process? Description When using the Quartus® Prime Pro Edition Software version 18.0, if the SmartVID (-V) graded Stratix® 10 FPGA device is configured in PMBus slave mode, the Stratix® 10 FPGA device will not respond to any PMBus commands during the Partial Reconfiguration process. If the master power management controller queries the Stratix® 10 FPGA device for a voltage update during Partial Reconfiguration, the Stratix® 10 FPGA device will not respond. Resolution After the Partial Reconfiguration process is complete, the Stratix® 10 FPGA device will respond to the queries again. The master power management controller needs to reissue the queries until it gets a response. Custom Fields values: ['novalue'] Troubleshooting 2205966595 False ['novalue'] ['FPGA Dev Tools Quartus® Prime Software Pro'] novalue 18.0 ['Stratix® 10 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2024-10-25