Why do I see a "System.xcvr: "Number of lanes" (lanes) (1) out of range (1,0)" Qsys error when upgrading Stratix IV GX and Arria II GX transceiver toolkit designs between different versions of the Quartus II software? - Why do I see a "System.xcvr: "Number of lanes" (lanes) (1) out of range (1,0)" Qsys error when upgrading Stratix IV GX and Arria II GX transceiver toolkit designs between different versions of the Quartus II software?
Description Due to a problem in the Quartus® II archiving software you may see the above Qsys error when upgrading Stratix® IV GX and Arria® II GX transceiver toolkit designs between different versions of the Quartus II software. This is due to the Quartus II Archiver not importing the design "IP" folder. Resolution To fix this issue copy the "IP" folder to your project. The IP folder can be found in the Transceiver Toolkit example designs. Related Articles Why do I see the following Qsys warnings when I open a Quartus II 13.0sp1 version of a Stratix IV GX/T Transceiver Toolkit example design?