Is INIT_DONE a required signal when using SmartVID on Intel Agilex® 7 devices? - Is INIT_DONE a required signal when using SmartVID on Intel Agilex® 7 devices?
Description Contrary to the statement in the Intel Agilex® 7 Configuration User Guide it is not a requirement to enable INIT_DONE when using SmartVID on Intel Agilex® 7 devices. Resolution There may be some use cases where it is useful to monitor INIT_DONE externally when using SmartVID. If the FPGA is in PMBus Master mode and there are other masters on the bus, INIT_DONE could be used to let the other master(s) know when its OK to talk on the bus. If the FPGA is in PMBus Slave mode, INIT_DONE can be used by an external master to know when to start polling with VOUT_COMMAND. This information will be added to a future revision of the Intel Agilex® 7 Configuration User Guide