Why does the EMIF Traffic Generator 2.0 (TG2) tool hang and/or show incorrect readdata when configured in sequential mode? - Why does the EMIF Traffic Generator 2.0 (TG2) tool hang and/or show incorrect readdata when configured in sequential mode?
Description Due to a problem in the Intel® Quartus® Prime Pro Edition software version 20.4 and earlier, The TG2 tool may hang or show incorrect readdata when used in sequential mode. This issue occurs because when writing a burst of data starting at an address within the last 127 address space, with a burstlength of 127, the TG2 will attempt to write data to addresses that fall outside the memory module, causing an overflow. Resolution This issue only occurs when using sequential mode . However, when using random mode or random-sequential mode , the TG2 accounts for the burstlength when generating the memory address to avoid overflow. This problem is fixed starting with the Intel® Quartus® Prime Pro Edition Software version 21.1.