Why does the niosv-bsp command report “Error - Unrecognized switch <b>qsys</b>” when using the Quartus® Prime Standard Edition Software? - Why does the niosv-bsp command report “Error - Unrecognized switch <b>qsys</b>” when using the Quartus® Prime Standard Edition Software? Description To create a BSP setting file using the niosv-bsp command, for the Quartus® Prime Pro Edition Software, use the .qsys file as the input file, but for the Quartus® Prime Standard Edition Software, use the sopcinfo file as the input file. niosv-bsp command in the Quartus® Prime Pro Edition Software: niosv-bsp -c --quartus-project=hw/top.qpf --qsys=hw/sys.qsys \ --type=<hal or ucosii> sw/bsp_custom/settings.bsp niosv-bsp command in the Quartus® Prime Standard Edition Software: niosv-bsp -c --sopcinfo=hw/sys.sopcinfo \ --type=<hal or ucosii> sw/bsp_custom/settings.bsp Resolution The Nios® V Embedded Processor Design Handbook (version 23.4 and later) adds such clear information. Custom Fields values: ['novalue'] Troubleshooting 15014187782 False ['novalue'] ['FPGA Dev Tools Quartus® Prime Software Standard'] 23.4 23.1 ['Cyclone® Bare Die', 'MAX® CPLDs'] ['novalue'] ['novalue'] ['novalue'] - 2025-03-03