Why is there a functional failure such as a PCIe/Ethernet link-up failure after reconfiguration of an Intel Agilex® 7 device has been completed successfully using the Intel® Quartus® Prime Pro Edition Software version 22.1? - Why is there a functional failure such as a PCIe/Ethernet link-up failure after reconfiguration of an Intel Agilex® 7 device has been completed successfully using the Intel® Quartus® Prime Pro Edition Software version 22.1? Description Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 22.1, if you are using an Intel Agilex® 7 device in Active Serial (AS) configuration mode and using Programming File Generator version 22.1 to generate the configuration bitstream from the .sof file, you might see a functional failure, such as a PCIe/Ethernet link up failure after reconfiguration has completed successfully. Resolution To fix this problem, use the Programming File Generator from the Intel® Quartus® Prime Pro Edition Software version 22.2 and install the following patch: Intel® Quartus® Prime Pro Edition Software v22.2 Patch 0.11fw for Linux (.run) Intel® Quartus® Prime Pro Edition Software v22.2 Patch 0.11fw for windows (.exe) Readme for Intel® Quartus® Prime Pro Edition Software v22.2 Patch 0.11fw (.txt) Custom Fields values: ['novalue'] Troubleshooting 15011250476 False ['novalue'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 22.2 22.1 ['Agilex™ 7 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2023-05-25