FIR Filters With Large Numbers of Coefficients and Non?Symmetric Structure Do Not Generate Netlist and IPFS Model Correctly - FIR Filters With Large Numbers of Coefficients and Non?Symmetric Structure Do Not Generate Netlist and IPFS Model Correctly
Description FIR filters with large numbers of coefficients and with Force Non-Symmetric Structure turned on, cannot generate a netlist successfully. FIR filters with large numbers of coefficients and with Force Non-Symmetric Structure turned on. The Quartus II software cannot generate a netlist or an IP functional simulation model. Resolution For FIR filters with Force Non-Symmetric Structure turned on, restrict the set of coefficients to 1500 or fewer.