If using the external Temperature Sensor, how can we translate the 8 digit number to the real temperature? - If using the external Temperature Sensor, how can we translate the 8 digit number to the real temperature?
Description If you are using the Altera recommanded Temperature sensor (8 digit) you may refer to following chart for the temperature decipher: Value of tsdcalo[7:0] in Hexadecimal Temperature in Degree Celsius (°C) FF 127 ... ... E4 100 ... ... D5 85 ... ... D0 80 ... ... B2 50 ... ... 9E 30 ... ... 8A 10 ... ... 80 0 ... ... 76 -10 ... ... 6C -20 ... ... 62 -30 ... ... 4E -50 ... ... 3A -70°C