Why are Hex files not generated when initialize memory content is enabled in my Intel® Arria®10 design? - Why are Hex files not generated when initialize memory content is enabled in my Intel® Arria®10 design?
Description Due to a problem in the Quartus® II Software version 14.1, Memory Initialization or Hexadecimal (Intel-Format) files are not generated when the "Initialize memory content" option is enabled in the "Memory initialization" section for the On-chip Memory IP in Qsys designs targeting Intel® Arria® 10. Resolution To workaround this problem in the Quartus® II Software version 14.1, follow the steps below: 1) Disable the "Initialize memory content" check box in the Memory Initialization section for On-chip Memory in Qsys. 2) A Memory Initialization File or Hexadecimal (Intel-Format) file will be generated. This problem is fixed with the Quartus® II software version 15.0.
Custom Fields values:
['novalue']
Troubleshooting
NA
False
['novalue']
['FPGA Dev Tools Quartus II Software']
15.0
14.1
['Arria® 10 GT FPGA', 'Arria® 10 GX FPGA', 'Arria® 10 SX FPGA']
['novalue']
['novalue']
['novalue'] - 2023-04-25
external_document