Error: TB_Gen: More than one reset ports found - Error: TB_Gen: More than one reset ports found
Description Due to a problem in Quartus® II software version 13.0 and later, you may see this error message when you generate a Qsys testbench. This error occurs if a Qsys component has an exported reset interface that includes a reset_request port. Resolution To work around this problem, perform one of the following actions: Do not export the reset interface Export the reset interface from a different component that does not include the reset_request port This problem is scheduled to be fixed in future release of the Quartus II software.
Custom Fields values:
['novalue']
Troubleshooting
novalue
False
['novalue']
['FPGA Dev Tools Quartus II Software']
novalue
13.0
['Programmable Logic Devices']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document