Error (175005): Could not find a location with: RST_SRC_ID of <value> - Error (175005): Could not find a location with: RST_SRC_ID of <value> Description When you implement multiple External Memory Interface IP cores in an Arria® 10 device and place them in the same I/O column, you may see the following fitter error if you feed the global_reset_n input of each interface with a different reset signal. Error (16234): No legal location could be found out of 1 considered location(s). Reasons why each location could not be used are summarized below: Error (175005): Could not find a location with: RST_SRC_ID of < value > (1 location affected) Unlike external memory controllers with UniPHY, all interfaces of the Arria 10 External Memory Interfaces in the same I/O column must share the same reset signal. Resolution To avoid this fitter error, use same reset signal for all the memory controllers in the same I/O column. Custom Fields values: ['novalue'] Troubleshooting novalue False ['novalue'] ['novalue'] novalue novalue ['Arria® 10 FPGAs and SoCs', 'Arria® 10 GX FPGA'] ['novalue'] ['novalue'] ['novalue'] - 2021-08-25