Why does tx_ready fail to assert on my F-Tile PMA/FEC Direct PHY FPGA IP bonded variant with the Datapath clocking mode parameter set to “PMA”, the PMA width parameter set to “32”, and the Enable TX double width transfer parameter unselected? - Why does tx_ready fail to assert on my F-Tile PMA/FEC Direct PHY FPGA IP bonded variant with the Datapath clocking mode parameter set to “PMA”, the PMA width parameter set to “32”, and the Enable TX double width transfer parameter unselected? Description Due to a problem in the Quartus® Prime Pro Edition Software version 23.4, tx_ready will fail to assert on the F-Tile PMA/FEC Direct PHY FPGA IP bonded variant with the Datapath clocking mode parameter set to “PMA”, the PMA width parameter set to “32” and the Enable TX double width transfer parameter unselected . Resolution There is no workaround for this problem. This problem has been fixed starting in version 24.3 of the Quartus® Prime Pro Edition Software. Custom Fields values: ['novalue'] Troubleshooting 18037452415 False ['F-Tile PMA/FEC Direct PHY IP'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 24.3 23.4 ['Agilex™ 7 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2025-05-21