Why might the unaligned access of back-to-back single beat D2H ST transactions not be transmitted completely by Scalable Scatter-Gather DMA IP? - Why might the unaligned access of back-to-back single beat D2H ST transactions not be transmitted completely by Scalable Scatter-Gather DMA IP?
Description Due to a problem in the Quartus® Prime Pro Edition Software version 24.3.1 and earlier, unaligned access of back-to-back single beat D2H ST transactions might not be transmitted completely by Scalable Scatter-Gather DMA IP. As a result, the device port might hung and soft reset is required to resume subsequent transactions. Resolution This problem is scheduled to be fixed in a future release of the Quartus® Prime Pro Edition Software.
Custom Fields values:
['novalue']
Errata
16025679490
False
['Scatter-Gather DMA Controller IP']
['FPGA Dev Tools Quartus® Prime Software Pro']
25.1
24.3
['Agilex™ 5 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2025-01-23
external_document