Why does the quartus_pgm command for checking the configuration status not work in Intel® Quartus® Prime Pro Edition Software version 23.2? - Why does the quartus_pgm command for checking the configuration status not work in Intel® Quartus® Prime Pro Edition Software version 23.2? Description In Intel® Quartus® Prime Pro Edition Software version 23.2, you may observe that the command line below to check the configuration status of Intel Agilex® 7 or Intel® Stratix® 10 devices using the quartus_pgm command is not working. quartus_pgm -c <cable> -mjtag --status Resolution To work around this problem, you can use Configuration Debugger Tool or send the SDM mailbox command CONFIG_STATUS [0x4] to check the configuration status. Refer to Intel Agilex® 7 Configuration User Guide, Intel® Stratix® 10 Configuration User Guide, and Mailbox Client Intel® FPGA IP User Guide for more information about the CONFIG_STATUS command. This problem is planned to be fixed in a future release of Intel® Quartus® Prime Pro Edition Software. Custom Fields values: ['novalue'] Troubleshooting 15013608466 False ['novalue'] ['FPGA Dev Tools Quartus® Prime Software Pro'] No plan to fix 23.2 ['Agilex™ 7 FPGAs and SoCs', 'Stratix® 10 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2023-06-26