Can the SEU FIT Reports be enabled in Intel® Quartus® Prime Pro Edition Software? - Can the SEU FIT Reports be enabled in Intel® Quartus® Prime Pro Edition Software? Description Yes, the Intel® Quartus® Prime Pro Edition Software can enable the SEU FIT Reports using the same assignment as Intel® Quartus® Prime Standard Edition. Refer to 1.6.3. Enabling the Projected SEU FIT by Component Usage Report in AN 866: Mitigating and Debugging Single Event Upsets in Intel Quartus Prime Standard Edition for the required assignment. After enabling the SEU FIT Reports , you can see the SEU FIT Parameters and Projected SEU FIT by Component Usage reports under the Finalize Stage of the Fitter in the Compilation Report. Resolution Intel® Stratix® 10 SEU Mitigation User Guide has been updated to include this information AN 737: SEU Detection and Recovery in Intel® Arria® 10 Devices will be updated to include this information in a future release. Custom Fields values: ['novalue'] Troubleshooting 14014357993 False ['novalue'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 22.4 21.1 ['Agilex™ 7 FPGAs and SoCs', 'Arria® 10 FPGAs and SoCs', 'Cyclone® 10 FPGAs', 'Stratix® 10 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2023-06-11