Error: libbytestream.so ELF 32 class not present - Error: libbytestream.so ELF 32 class not present Description Due to a problem in the Quartus® II software, this error may occur when sourcing the libbytestream_pli.so library with the ModelSim®-Altera software or other simulation tools. This error occurs because the simulation tools are expecting a 64-bit version of the library, but only the 32-bit version is found. Resolution To work around this issue, delete the following code from the msim_setup.tcl file for ModelSim-Altera (or other corresponding setup script for the simulation tool you are using). -pli <library directory> /libbytestream_pli.so This problem is scheduled to be fixed in a future version of the Quartus II software. Custom Fields values: ['novalue'] Troubleshooting novalue False ['novalue'] ['novalue'] novalue novalue ['Programmable Logic Devices'] ['novalue'] ['novalue'] ['novalue'] - 2021-08-25