Is the weak pull-up feature supported in bank 3C of Intel® Stratix® 10 GX 400 and SX 400 devices? - Is the weak pull-up feature supported in bank 3C of Intel® Stratix® 10 GX 400 and SX 400 devices?
Description Although documented as supported in Intel® Stratix® 10 General Purpose I/O User Guide and allowed in Intel® Quartus® Prime Pro Edition software version 20.1 and earlier, the weak pull-up feature is in fact not supported in bank 3C of Intel® Stratix® 10 GX 400 and SX 400 devices. Resolution The weak pull-up option for bank 3C is scheduled to be removed starting with the Intel Quartus Prime Pro Edition software version 20.2.
Custom Fields values:
['novalue']
Troubleshooting
1507935938
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
20.2
20.1
['Stratix® 10 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2022-01-19